What happened
A Conti ransomware intrusion hit Ireland's Health Service Executive. Attackers encrypted systems and stole data; the HSE took its network offline to contain it, which cut clinicians off from systems across the country and forced manual workarounds. The state auditor later reported that full systems access was not restored until late September 2021, more than four months on.
What the PwC review found
PwC's post-incident review described the National Health Network as primarily flat and unsegmented, and said that this design, together with complex administrator permissions, let the attacker reach systems across many connected organisations and magnified the incident. It also described weak boundaries between organisations and bidirectional Active Directory trusts, which are an identity problem as much as a network one. Nobody should read this as "one firewall rule would have stopped Conti". It does mean that when the attacker arrived, very little was in the way.
Hospital site network must not reach other organisations' servers
In a distributed network the question is which specific boundaries are supposed to hold between endpoint, server, management and remote-site segments. Those are testable one declared path at a time. Trust abuse and admin permissions are not; Segproof says nothing about them.
Sources: PwC independent post-incident review, December 2021 (printed pages 6 and 36 on the flat network; page 48, finding FA1.KF8; page 61, the segmentation recommendation) · Comptroller and Auditor General, 2022 · Dáil answer, 27 March 2025